Gas and dust groups, typical substances and temperature classifications according to ATEX and IECEx and US and Canadian certification systems.

Note that the EN and IEC Standards are harmonized so from a product standpoint, about 80%+ of the products out there that have ATEX (For Zone 0 & 1 applications) most likely have an IECEx certificate which is valid for other parts of the world (but not Europe..)

International System – CENELEC and IEC Zone Classifications. Zone Classifications. Class I, Zone 0 A location in which explosive gas atmospheres are present continuously or for long periods of time. A typical example would include a vapor space in a vented tank. Class I, Zone 1

Effective ignition source is a term defined in the European ATEX directive as an event which, in combination with sufficient oxygen and fuel in gas, mist, vapour or dust form, can cause an explosion. Methane, hydrogen or coal dust are examples of possible fuels. Effective ignition sources are: Lightning strikes. Open flames.

Control Stations & Push Buttons. Hazardous area control stations, surface or panel mounted, specified for potentially explosive atmospheres and suitable for Zone 1 gas and Zone 21 dust environments (including Zone 2 & 22) – manufactured from stainless steel, plastic or GRP with various push buttons, emergency stops, switches, mushroom heads and indicator lamps integrated into control station.

Rest of World: Zone 2 IIB 3 ATEX – IEC 60079-13 – Equipment protection by pressurized room "p". An TFTC or ATEX/IEC Ex fan draws in clean, uncontaminated typically through an 24ft, 8m high inlet stack. The units maintain a slight positive air-pressure in the room, compensating for: normal air-leakage

A collection of data to clearly outline hazardous area protection concepts for mechanical and electriacl equip. including ATEX and pre-ATEX.

The coal mining, chemical and petrochemical sectors are of particular concern, but the food industry, mill operation, wastewater and biogas production sectors are also affected. These combustible substances can form a potentially explosive atmosphere ... Primary explosion protection refers to all measures that

fibers/flyings. In the European community (IEC/ATEX), and some other countries, the Zone scheme is used. The zone classification schemes may also be used to classi-fy hazardous areas in the US. The fuels may be further broken down according to Groups. Tables 1 and 2 provide relevant information with regard to the differences be-tween the two ...

Zone 2 is the same as Division 2 and refers to hazards that are present only under abnormal circumstances. Chart 1 below compares the definitions of Zones 0, 1, and 2 and Divisions 1 and 2. Materials that react most violently when ignited are classified by the IEC method as Group IIC, which encompasses both Groups A and B of the North American

– Flour mills – Feed mills – Grain elevators and grain handling facilities ... Equivalent zone markings NEC Article 505 and 506 define a North American System of Zone Classification for Gas & Dust. Most Baldor•Reliance division ... NEMA explosion proof AC and DC motors (IEC) ...

IECEx/ATEX: Defining and Certifying Explosion-Protected (Ex) Safety Standards ... Both IECEx and ATEX align with the same standards (e.g., IEC-EN 60079), so in terms of technical content, there is basically no difference. ... EPL is an IEC designation which is similar to the ATEX Category & Zone designation, as shown in the GORE® PolyVent Ex+ ...

ATEX puts equipment into Groups and Categories based on the type of environment the equipment is intended to be used in, and the level of protection provided by the equipment. There are two Equipment Groups: Group I – equipment intended for use in underground parts of mines, and in those parts of surface installations of such mines, liable to ...

AIN CONCEPTS OF ELECTRICAL PROTECTION ACCORDING TO ATEX AND IECEx Rules of reference Mode of protection Zone Symbol EPL Basic function Scheme IEC/EN Gas Dust Gas Dust Gas Dust Gas Dust 60079-14 Design, selection and installation of electrical systems Defines the design criteria of the plant explosion-proof 60079-0 General requirements

Specifying Temperature Sensors for Hazardous Areas . The manufacture of petroleum products, paint, and ... coal mines, textile mills, dry cleaning facilities, and plants that create sawdust or flyings, to name a ... (IEC) has developed the Zone system, described in their specification IEC 60079. It .

ATEX and IECEx Standards for Intrinsically safe load cells for hazardous areas explained Here is an explanation of ATEX and IECEx standards, markings, classification, directive and different zones. ATEX products are differentiated from standard products by their markings, most noticeably the .

The relation between the ATEX 1999/92/EC and the IEC is indicated below : in the Zone 0 you could mount an equipment Ga or 1G (according to 94/9/EC ATEX). ATEX 2014/34/EU directive classifies the equipment into categories 1,2,3 (Group II), based on protection level. Standard EN/IEC 60079-0 introduces EPL (Equipment Protection Level).

Mar 11, 2019· Home » About Us » News » Hazardous Environment Classifications: NEC vs IEC. Hazardous Environment Classifications: NEC vs IEC. Posted March 11, 2019 by springercontrols. When working in or specifying equipment for use in hazardous environments, we see a lot of confusion in the industry regarding the different certifications and requirements.

ATEX Area Classifications/Zoning Definitions. ... With reference to the descriptions shown below it can be seen that the definition of any particular zone is based on the frequency of exposure to the hazardous material. Equipment Groups. Hazardous areas can usually be classified into three groups, I, II and III.

Marking to Directive 94/9/EC (ATEX 95) 0518 Number of the noti˜ed body "We specialize in IEC/ATEX/EX Electrical Equipment for use in Hazardous/Industrial Environments" Zone 0 A place in which an explosive atmosphere consisting of a mixture with air of flammable

ised design regulations were formulated in IEC standards at a very early stage. For the most part, this was done in conformance with the CENELEC standards. A visible sign of the harmonisation is that the relevant IEC/ISO World, EN Eu-rope and DIN EN Germany documents on standards agree in content and in the registration number (IEC 60079 ff ).

Symbol Zone 0 Zone 2 Marking Ex ia, Ex ma or Ex da or a suitable combination of two separate protection concepts Ex i Ex m Ex e Ex o Ex p Ex q Ex d Ex n Ex t Ex op Basic principle Attention should be paid to the following for Zone 0: surface temperatures should not exceed 80% of the igniti-on temperature of the gas, even in the event of rarely oc-

Excluded as per IEC 60079-10-1 IEC 60079-10-1 Classification of areas - Explosive gas atmospheres Standard intended to be applied where there may be an ignition hazard due to the presence of flammable gas orpresence of flammable gas or vapour, mixed with air under normal, mixed with air under normal atmospheric conditions but does not apply to :

EU ATEX Directives and standards. October 2015 Page 2 In the general framework of implementation of EU Directives and ... ZONE 2 ZONE 1 ZONE 0 Category 3 Category 2 Category 1 Probability of an ingnition Probability of ... 10-1) the relevant European committee (IEC-CENELEC) agreed on leaving to the designer the flexibility to perform his own